You are here:
With loop anchors. For flush installation in concrete decks with coating systems
Central insert with double-web to provide multilayered protection
Visual inspection and replacement without disrupting the surface
100% watertight by max. pressure
Proper and economical connection of the coating system
Slidable loop anchors for adjustable welding to the reinforcement
Standard version | Joint width max. [mm] | Total movement [mm] | Joint width visible [mm] | Total width [mm] | Joint height [mm] | Load bearing capacity private cars [kN] | Load bearing capacity lorris (DIN 1072) [kN] | Load bearing capacity forklift trucks acc. (DIN 1055) [kN] | Load bearing capacity special vehicles with solid plastic tyres [kg/mm] |
---|---|---|---|---|---|---|---|---|---|
FP 80/90 B NI | 21 | 20 (±10) | 82 | .. | 100 | 35 | 600 | 130 | 6,5 |
FPG 80/90 B NI | 21 | 16 (±8) | 82 | 100 | 35 | 600 | 130 | 6,5 | |
FP 90/90 B NI | 34 | 40 (±20) | 95 | 100 | 35 | 600 | 130 | ||
FPG 90/90 B NI | 34 | 20 (±10) | 95 | 100 | 35 | 600 | 130 | 4,3 | |
FP 110/90 B NI | 50 | 60 (±30) | 111 | 100 | 35 | 600 | 130 | ||
FPG 110/90 B NI | 50 | 40 (±20) | 111 | 100 | 35 | 600 | 130 | ||
FP 130/90 B NI | 74 | 90 (±45) | 133 | 100 | 35 | 300 | 70 | ||
FP 155/90 B NI | 94 | 120 (±60) | 155 | 100 | 35 | 300 | 70 |
* FP 155/90 B NI: Bfl, s2
Sealing against nonpressurized water.
Distance of anchor loops ≤ 340 mm
Corner version | Joint width max. [mm] | Total movement [mm] | Joint width visible [mm] | Total width [mm] | Joint height [mm] | Load bearing capacity private cars [kN] | Load bearing capacity lorris (DIN 1072) [kN] | Load bearing capacity forklift trucks acc. (DIN 1055) [kN] | Load bearing capacity special vehicles with solid plastic tyres [kg/mm] |
---|---|---|---|---|---|---|---|---|---|
FP 80/90 B NI E3 | 21 | 20 (±10) | 92 | 100 | 35 | 600 | 130 | 6,5 | |
FPG 80/90 B NI E3 | 21 | 16 (±8) | 92 | 100 | 35 | 600 | 130 | 6,5 | |
FP 80/90 B NI E4 | 21 | 20 (±10) | 56 | 100 | 35 | 600 | 130 | 6,5 | |
FPG 80/90 B NI E4 | 21 | 16 (±8) | 56 | 100 | 35 | 600 | 130 | 6,5 | |
FP 90/90 B NI E3 | 34 | 40 (±20) | 105 | 100 | 35 | 600 | 130 | ||
FP 90/90 B NI E4 | 34 | 40 (±20) | 69 | 100 | 35 | 600 | 130 | ||
FPG 90/90 B NI E3 | 34 | 20 (±10) | 105 | 100 | 35 | 600 | 130 | 4,3 | |
FPG 90/90 B NI E4 | 34 | 20 (±10) | 69 | 100 | 35 | 600 | 130 | 4,3 | |
FP 110/90 B NI E3 | 34 | 60 (±30) | 121 | 100 | 35 | 600 | 130 | ||
FP 110/90 B NI E4 | 34 | 60 (±30) | 85 | 100 | 35 | 600 | 130 | ||
FPG 110/90 B NI E3 | 34 | 40 (±20) | 121 | 100 | 35 | 600 | 130 | ||
FPG 110/90 B NI E4 | 34 | 40 (±20) | 85 | 100 | 35 | 600 | 130 | ||
FP 130/90 B NI E3 | 74 | 90 (±45) | 143 | 100 | 35 | 300 | 70 | ||
FP 130/90 B NI E4 | 74 | 90 (±45) | 107 | 100 | 35 | 300 | 70 | ||
FP 155/90 B NI E3 | 94 | 120 (±60) | 165 | 100 | 35 | 300 | 70 | ||
FP 155/90 B NI E4 | 94 | 120 (±60) | 129 | 100 | 35 | 300 | 70 |